LT Power Cables
Aerial Cables
Control Cables
Instrumentational Cables
Stay Cables
Panel Flex Cables Product
Ripcord Cables Quality
Surfix Cables Process
Hardwares Product Range
Control Cables SABS Approved Product
Control Cables Follow us
 
Control Cables Control CablesControl CablesControl Cables
Control Cables Contact Us

Name :

Phone :

E-mail :

Country :

Comments :

Enter Your Code Shown :

  Control Cables

   

Control Cables Brochures
SABS Approved Electric Cable Catalog
Click here to Download
Complete Cable Catalog
Click here to Download
Medium Voltage Electric Cable Catalog (3.3kv to 33kv)
Click here to Download
Flattwin and Earth Cables
1kV Flexible power Cables
LT Power Cables
Instrumentational Cables Thermocouple Cables Railway Signalling Cables Buired Service Cables Installation Cables Conductors Flexible Cables Mining Cables FRLS Cables Submersible Cables HR Cables Custom Made Cables Stay Cables
Thermocouple Cables
Railway Signalling Cables
Buired Service Cables ( GEMINI FRLS CABLES)
Installation Cables
 
Gemini FRLS Cables
Whenever fire breaks-out in any building/complex, the burning of wire emanates, the toxic black smoke, which causes injury and subsequently becomes fatal to the human life. This compelled us to develop FRLS ( FIRE RETARDENT LOW SMOKE ) Wires. These wires are quite safe during the fire break-out.
 
Construction
  • Conductor : Bare annealed tinned copper
  • Insulation : Double layer insulation FRLS grade PVC
  • Standard : IS 694( Under Consideration )
  • Sizes : 0.5 sq.mm to 50sq.mm
 
Application

Tirupati Plastomatics FRLS wire are ideal for use in densely populated areas :-

  • Houses
  • Buildings
  • Flats
  • Apartments
  • Factories
  • Hospitals
  • Theaters
  • Education Institutions

And also used with UPS, Invertor, Battery, Control panels etc. As well as areas where safety is a major criteria.

 
TECHNICAL DATA
Nominal Cross Sectional Area of the Conductor sq.mm Nos./ Nominal Dia of Strand No./ (mm) Nominal Thickness of Insulation (mm) Approx. Overall Dia (mm) Conductor Resistance at 20°C Max. ohm/km Current Rating (Amps.)
2 Wires In Conduit/ Trunking 1Phase # Clipped Directly to surface or on cable Tray
1.0 *14/.3 0.7 2.8 18.1 11 12
1.5 *22/.3 0.7 3.1

12.1

13 16
2.5 *36/.3 0.8 3.8 7.41 18 22
4.0 **56/.3 0.8 4.3 4.95 24 29
6.0 **84/.3 0.8 5.2 3.30 31 37
 
Note: Std Colours - Red, Yellow, Blue, Black & Green (All colours come with white strip Normal packing length - 90 mtrs.)
*Conductor : Class 2 as per IS : 8130 : 1984
**Conductor : Class 5 as per as IS : 8130-1984
#As per IS : 3961 Part (5)
 